Phone:  (08) 9445 2755

Cart

POWERHOUSE 12V 120AH LiFeP04 LITHIUM BATTERY

POWERHOUSE 12V 120AH LiFeP04 LITHIUM BATTERY

$999.00

In stock

We cannot ship all products Australia Wide. Please enter you post code to see if we can ship this product to your area //

Compare

Share this product

Description

DESCRIPTION

This 12.8V 120Ah lithium battery (LiFePO4) is compatible in size with traditional 90-130Ah SLA batteries (check dimensions), but with all the benefits of cutting edge lithium technology. LiFePO4 batteries offer longer service life than traditional lead acid batteries, plus weigh less than HALF as much as SLA batteries. LiFePO4 also provide more usable life per cycle, allowing for longer run times by holding a higher voltage until capacity is almost exhausted. These batteries will also maintain 80-90% charge when in storage – far higher than their lead acid counterparts. The latest generation in maintenance free batteries is here!

Each battery is fitted with an internal battery management system to provide safe charging and discharging at all times. This system provides internal short circuit, over temperature and under/over voltage cut off. Can be wired in series and/or parallel. When used in series each battery will need to be discharged to cut off before connecting so that all cells are all balanced.

Suitable for recharging with the mains battery charger models listed in the accessories below.

Excessive temperatures over 65ºC can effect the ABS housing. Need to be well ventilated in warm conditions. Not for use in engine bays.

Features

  • Internal battery management system for safe charging and discharging.
  • Drop in replacement for standard lead acid 90-130Ah batteries (check dimensions)
  • Half the weight of traditional lead acid batteries.
  • Less discharge when in storage compared with traditional lead acid batteries.
  • Longer service life compared to lead acid.
  • Longer run time compared to lead acid.
  • Factory supplied at 30% charge for safety compliance. Must be charged fully before use.
  • 100A DISCHARGE BMS
  • 3 YEAR WARRANTY

Specifications

    • General
    • Dimensions: 330 x 172 x 220mm
    • Overall Weight: 13.5kg
    • Terminal Type: M8 / F12
    • Connection: 12-48V max 4 in series, no limit in parallel.
    • Note: When used in series each battery will need to be discharged to cut off before connecting so that all cells are all balanced.
    • Case Material: ABS
    • Case IP Rating: IP56
    • Cell Type: Cylinder
    • Certification: CB/CE, UN38.3, UL1642 @ cell.
    • Shipping Class: UN3480, Class 9
    • Battery Module Specification
    • Nominal Voltage: 12.8V @ 25°C, 0.2C
    • Capacity: 120Ah @ 25°C, 0.2C
    • Operating Parameters
    • Charging Voltage: 13.8 – 14.4V
    • Discharging Voltage: 9.2V-15.4V (Recommended 11.8V)
    • Charging Current: 100A max, (Recommended 50A)
    • Max Constant Discharge: 100A
    • Pulse Discharge: 840A for 50mS
    • Temperature
    • Charge Range: 0 to 45°C
    • Discharge Range: -20 to 60°C
    • Storage Range: -20 to 45°C
    • Service Life
    • Design Life: >10 years @ 25°C, 0.2C
    • Cycle Life (25°C, 0.2C): >2000 times (100% DOD to 80% end)
    • Cycle Life (25°C, 0.5C): >4000 cycles (100% DOD to 50% end)
    • BMS Parameters
    • Charging
    • Cell Voltage Protection: 3.9V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38V or module voltage <13.52V)
    • Module Voltage Protection: 15.6V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38V or module voltage <13.52V)
    • Over Charging Current 1: 100A Delay 20-30S (Turn to pre-charge mode and try to recover in every 3 minutes)
    • Temperature Protection: <-10°C or >70°C, Delay 1-2S (Recovery when >0°C or <60°C)
    • Discharging
    • Cell Voltage Protection: 2.2V Delay 500mS (Recover when charge current >1A or cell voltage >2.6V or module voltage >10.4V)
    • Module Voltage Protection: 8.8V Delay 1-2S (Recover when charge current >1A or cell voltage >2.95V or module voltage >11.8V)
    • Over Discharging Current 1: 380-420A Delay 500-1500mS (Recover when charging current >1A, or recover in every 60S)
    • Over Discharging Current 2: 760-840A Delay 50-150mS (Recover when charging current >1A, or recover in every 60S)
    • Short Circuit: 200-700us
    • Temperature Protection: <-20°C or >75°C, Delay 1-2S (Recovery when >-10°C or <65°C)
    • BMS Features
    • PCB Temp Protection: >115°C Delay 1-2S Recover when <80°C
    • Cell Balance: 25-45mA passive balance cell voltage difference > 45mV
    • Temperature Accuracy: ±2°C Cycle measurement Measuring range -40 to 100°C
    • Voltage Accuracy: ±20mV Cycle measurement for cells and module
    • Current Accuracy: FSC±5% Cycle measurement measuring range -200 to +200
    • SOC: 5% (integral calculation)
    • Power Consumption: <300uA (switch off mode – storage), <100uA (sleep mode – protection & standby), <15mA (operating mode)

*Specifications are subject to change without notice.